Checker Chromium VI

Checker Chromium VI

Chromium is one of the elements that can be found in wastewater from a wide variety of industrial processes. Its toxicity depends on the oxidation state and concentration in which it is found, being of special importance the elimination of hexavalent chromium present in aqueous systems, as it is harmful to health.

Description

Características

Chromium IV pocket meters are digital colorimeters to perform chromium tests. They are supplied with cuvettes with lids, reagent for 6 tests, battery, instructions and quick guide for use.

  • Precise and simple measurements
  • Direct display of the Chromium VI value on the screen.

Depending on the range:

  • Low Range: 0 to 300 ppb
  • High Range: 0 to 999 ppb

Funcionamiento

Our meters are portable so they can be easily carried anywhere you need. And what’s more, the one-button operation will make you get accurate results in a simple way.

Step 1: Add a sample to the cuvette (included).
Step 2: Insert the sample into the checker and press the button to zero.
Step 3: Withdraw the sample and add the reagent as indicated in the manual.
Step 4: Reinsert the sample and press the button for 3 seconds to measure the results.

Aplicaciones

HANNA checkers are small, portable, and most importantly, they provide more accurate results than typical chemical test kits. Offering improved technology, its simple design allows for easy, hassle-free measurement.
These digital photometers or test kits serve as a bridge between the very simple test kit and professional instrumentation such as a calibratable photometer.

Tabla

HI749 HI723
Range 0 a 300 ppb 0 a 999 ppb
Resolution 1 ppb 1 ppb
Accuracy 25 ° C  ± 3 ppb ± 5% of reading ± 5 ppb ± 4% of reading
Light source LED a 525 nm LED a 525 nm
Light detector silicon photocell silicon photocell
Method Adaptation of ASTM Manual of Water & Environmental Technology, D1687-92, Diphenylcarbohydrazide method. The reaction between chromium VI and the reagent causes a purple tint in the sample. Adaptation of ASTM Manual of Water & Environmental Technology, D1687-92, Diphenylcarbohydrazide method. The reaction between chromium VI and the reagent causes a purple tint in the sample.
Environment 0 a 50 ° C; RH max. 95% non- condensing 0 a 50 ° C; RH max. 95% non- condensing
Power supply (1) 1.5V AAA (1) 1.5V AAA
Power auto off After 10 min of inactivity After 10 min of inactivity
Dimensions 86 mm x 61 mm x 37,5 mm 86 mm x 61 mm x 37,5 mm
Weight 64 g 64 g